How to operate an Air Separation Unit?

If you’ve ever stood beside an operating Air Separation Unit (ASU) at a industrial site, watching silent streams of oxygen, nitrogen, and argon flow into connected pipes for steel manufacturing, food freezing, or pharmaceutical packaging, you might assume the process runs on unchanging, automated settings. But as someone who’s spent 12 years designing, troubleshooting, and supplying ASUs for mid-sized industrial facilities, I can tell you operating these units is equal parts science, attention to detail, and quick problem-solving—especially when you’re working with cryogenic temperatures that can cause injury, pressure swings that damage equipment, and purity specs that make or break a customer’s bottom line. Today, I’m walking through the step-by-step, field-proven process I teach our customers and own techs, plus the critical checks that keep an ASU running safely and efficiently. Air Separation Unit

First, let’s get the basics straight: an ASU isn’t a single machine, it’s a system of interconnected components that separate atmospheric air into its core elements via cryogenic distillation (cooling air to liquefy it, then boiling off each gas at its unique boiling point) or membrane separation for smaller, lower-demand operations. For large-scale customers—steel mills, chemical plants, or cryogenic tank farms—cryogenic is the standard, and that’s what we specialize in. Every ASU we supply comes with a custom operation manual, but these are the universal steps that apply to almost all cryogenic ASUs, adjusted for unit size and gas output.

The process starts long before you flip a single switch: pre-start inspections. This isn’t a rushed walkaround—this is where 80% of ASU startup issues are caught. I make every new customer’s operations team run through this checklist twice, especially if the unit has been idle for more than a week. First, confirm all safety interlocks are active: pressure relief valves on the distillation column and liquid storage tanks are calibrated correctly, emergency stop (E-stop) buttons are unblocked and functional, and gas detectors for oxygen-rich and nitrogen-rich areas are powered on. Nitrogen displaces oxygen quickly, so even a small leak in a confined space can lead to unconsciousness in seconds—we’ve had a customer almost miss a cracked valve seal during pre-start, so this step is non-negotiable. Next, check the air intake filter and pre-cooling system: a clogged filter will force the compressor to work 20% harder than it should, wasting energy and shortening component life. We supply replacement filters with every unit, but remind teams to check them daily, especially in dusty or high-humidity environments. Finally, verify all valves are in the correct positions: shut-off valves for the product lines are closed, while purge valves for the distillation column are open to clear out moisture and residual gas.

Once pre-start checks are done, the next step is compressing and purifying the raw air. The heart of this stage is the main air compressor (MAC), a large, oil-free unit that pulls in atmospheric air and pressurizes it to 5 to 6 bar (gauge pressure). Before starting the MAC, I always tell operators to vent a small amount of air through the relief valve first—this prevents pressure spikes when the compressor kicks on. After compression, the air is still full of water vapor, carbon dioxide, and hydrocarbon traces that would freeze and clog the distillation column pipes at cryogenic temperatures. So we pass it through a pre-treatment system: first, an after-cooler that drops air temperature to 40°C, then a molecular sieve bed that traps CO2 and water, and finally a hydrocarbon adsorber to remove any leftover volatile compounds. The sieve beds need to be regenerated every 12 to 18 months, and we include a regeneration schedule with every ASU we supply—skipping this step is the top cause of column blockages. I once had a customer ignore the regeneration schedule for two years, and they spent $120,000 repairing a clogged distillation column; now, we send automated email reminders to their maintenance team, and it’s saved them thousands.

Next comes the cryogenic cooling stage, where the magic happens. The purified, pressurized air flows into the main heat exchanger, a large, coiled system made of stainless steel that cools the air to -170°C using a reverse flow of already separated cold gas (usually nitrogen). This is where the Joule-Thomson effect kicks in: when a pressurized gas is expanded rapidly, it loses temperature sharply. The cooled air then enters the distillation column, a tall, insulated tank with stacked trays or packing material that works like a series of small boiling pots. Liquid air pools at the bottom of the column; nitrogen, which boils at -196°C, evaporates first and rises to the top, while oxygen (boiling at -183°C) stays liquid at the bottom. Argon, the middle gas, collects between the two, so if your ASU produces argon, there’s a smaller secondary column to separate that out.

Now, here’s where operation gets tricky: stabilizing the column. A newly started column will have uneven temperatures across the trays, so operators need to slowly adjust the valve that controls liquid flow back into the top of the column to create a balanced “reflux” flow. Too much reflux, and nitrogen purity drops; too little, and the column can flood, damaging the trays. I always advise new operators to use a temperature probe at the top of the column as a guide: target a steady -196°C at the top, and adjust the valve in 5% increments if it shifts by more than 2°C. This stabilization phase can take 6 to 12 hours for a medium-sized ASU, and it’s tempting to speed it up, but rushing almost always leads to purity issues. Once the column is stable, you can start drawing off products: gaseous nitrogen from the top, liquid oxygen from the bottom, and liquid argon (if applicable) from the middle.

Routine operation isn’t just set-it-and-forget-it—daily checks keep efficiency high. First, monitor gas purity readings every 4 hours: for medical-grade oxygen, purity needs to be 99.5% or higher, while industrial nitrogen is usually 99.9%. If purity drops, check the sieve bed’s efficiency (a quick test of the outlet gas’s moisture content) or the distillation column’s temperature gradient. Next, track pressure and flow rates: the MAC’s discharge pressure should stay between 5.2 and 5.8 bar, and any sudden 0.5 bar drop usually means a filter is clogged or a valve is leaking. I also tell customers to log liquid levels in the storage tanks daily—running tanks too empty can pull in air, contaminating products, while overfilling can cause liquid to flow back into the column, disrupting distillation.

Emergency response is another core part of operating an ASU, because cryogenic systems have unique risks. If a cryogenic liquid line ruptures, never try to patch it with a standard seal—liquid oxygen can make materials like carbon steel brittle or even explosive when mixed with organic materials. Instead, activate the E-stop immediately, vent the column, and evacuate the area; wait at least 2 hours before inspecting, as cold leaks can cause frostbite that’s not visible until the area warms. If a purity alarm goes off for oxygen, shut down the product draw-off line immediately—contaminated oxygen can be a fire hazard in storage tanks, and we’ve worked with a customer who had a small tank fire because they ignored a 1% purity alert. For nitrogen leaks (which are odorless and colorless), use gas detectors to confirm oxygen levels in confined spaces; if levels drop below 19.5%, evacuate until ventilation restores oxygen to safe levels.

As an ASU supplier, we don’t just sell equipment—we provide 24/7 support and on-site training for every customer’s operations team. Over the years, I’ve learned that the best ASU performance comes from operators who understand why each step matters, not just what buttons to press. That’s why we include hands-on training for our techs, plus a year of free troubleshooting calls if you run into issues. Whether you’re looking to upgrade an existing ASU or install a new unit tailored to your production needs, our team can walk you through the design, startup, and long-term maintenance to keep your gas supply reliable. If you’re ready to discuss your ASU requirements or have questions about operation best practices, reach out to our team to schedule a consultation and learn how we can support your industrial gas needs.

Small Air Separation Unit References

  1. Gas Processors Suppliers Association. (2020). Engineering Data Book, 15th Edition. Section 15: Cryogenic Separation and Air Separation Units.
  2. American Society of Mechanical Engineers (ASME). (2021). Safety Standards for Cryogenic Air Separation Systems. ASME B31.3.
  3. Air Separation Equipment Manufacturers Association (ASEMA). (2022). Operation and Maintenance Guidelines for Cryogenic ASUs.
  4. National Fire Protection Association (NFPA). (2021). Standard for Gaseous Oxygen Systems. NFPA 99.
  5. Cryogenic Society of America. (2020). Cryogenic Safety Handbook for Industrial Operations.

Xinxiang Jiale Intelligent Equipment Co., Ltd.
As one of the leading air separation unit manufacturers and suppliers in China, we also support customized service. Please feel free to buy high quality air separation unit for sale here from our factory. Contact us for more details.
Address: No.3913, 9th Floor, Unit 3, East Commercial and Office Complex, Baolong City Plaza, Hongqi District, Xinxiang City, Henan Province, China
E-mail: cc2397410@gmail.com
WebSite: https://www.jialeasu.com/